Texas Senate · 89th Legislature, Regular Session
Members who authored, joint-authored, or co-sponsored this bill.
SourceLegiScan (CC BY 4.0)89R
AI summary unavailable. We’re still building out our data, so newer and more active legislation has better coverage.
The Legislative Budget Board’s fiscal note projects no significant fiscal impact. Read the note
Each version links to the authoritative document on capitol.texas.gov.
S.B. No. 2835 AN ACT relating to municipal regulation of stairway requirements in certain apartment buildings. BE IT ENACTED BY THE LEGISLATURE OF THE STATE OF TEXAS: SECTION 1. Chapter 214, Local Government Code, is amended by adding Subchapter I to read as follows: SUBCHAPTER I. SINGLE STAIRWAY IN CERTAIN APARTMENT BUILDINGS Sec. 214.301. PERMITTED REGULATION OF APARTMENT BUILDING STAIRWAY REQUIREMENTS. (a) A municipality may exercise the
Statewide figures for the subjects tagged on this bill, to explore on the Data map. They describe Texas — not this bill or its effects.
SourceU.S. Census Bureau (ACS) & CDC PLACESstatewide Data layer
Each subject links to other 89R bills tagged the same way.
authority under this section regardless of whether the municipality has adopted local amendments to the International Building Code under Section 214.216(c). (b) A municipality may authorize an apartment building to have a single stairway only if the building: (1) does not have more than six stories above grade plane and is not a high-rise as defined by the International Building Code, as adopted under Section 214.216; (2) does not have more than four dwelling units on any floor; (3) has automatic sprinkler locations in each interior exit stairway, regardless of the type of stairway construction, that comply with the requirements prescribed by National Fire Protection Association Standard 13 for combustible stairways; (4) has: (A) an exterior stairway; or (B) an interior exit stairway for which the doors: (i) into the stairway from the interior of the building swing into the stairway regardless of the occupant load served; and (ii) from the interior exit stairway to the building exterior swing in the direction of exit travel; (5) has interior exit stairway enclosures that: (A) have a fire resistance rating of not less than two hours; and (B) do not contain an elevator opening; (6) has on each floor a corridor from each dwelling unit entry or exit door to an interior exit stairway, including any related exit passageway, that has a fire resistance rating of at least one hour; (7) does not have more than 20 feet between the entry or exit door of a dwelling unit and an exit stairway; (8) does not have more than 125 feet of exit access travel distance; (9) has an exit serving the portion of the building that contains two or more dwelling units that does not discharge through a portion of the building with a different occupancy category, including an accessory parking garage; (10) has an exit that terminates in an egress court for which the court depth does not exceed the court width, unless it is possible to exit the egress court to the public way in either direction; (11) does not have an opening within 10 feet of an unprotected opening into an exit stairway other than a required exit door that has a fire resistance rating of at least one hour; (12) has emergency escape and rescue openings that comply with Section 1031 of the International Building Code as adopted under Section 214.216 on each floor served by a single exit; (13) does not have an electrical receptacle in an interior exit stairway; and (14) has an automatic smoke and fire detection system that activates an occupant notification system that complies with Section 907.5 of the International Building Code as adopted under Section 214.216 installed in each: (A) common space outside of a dwelling unit; (B) laundry room, mechanical equipment room, and storage room; (C) interior corridor serving a dwelling unit; and (D) main floor landing or interior or exterior exit stairway. SECTION 2. This Act takes effect September 1, 2025. ______________________________ ______________________________ President of the Senate Speaker of the House I hereby certify that S.B. No. 2835 passed the Senate on May 9, 2025, by the following vote: Yeas 29, Nays 2. ______________________________ Secretary of the Senate I hereby certify that S.B. No. 2835 passed the House on May 27, 2025, by the following vote: Yeas 81, Nays 57, two present not voting. ______________________________ Chief Clerk of the House Approved: ______________________________ Date ______________________________ Governor
SourceTexas Legislative Council (capitol.texas.gov)official bill text (capitol.texas.gov)
SourceLegiScan (CC BY 4.0)subject tags
SourceTexas Legislative Council (capitol.texas.gov)89R
Recorded as a group vote — the source has the totals above but no individual member breakdown.
Recorded as a group vote — the source has the totals above but no individual member breakdown.
SourceLegiScan (CC BY 4.0)89R
SourceLegiScan (CC BY 4.0)official fiscal notes & analyses (TLC)
Perch never collects comments itself — it points you to the Legislature's own hearing schedule and official public-comment channels (ADR-0007).
Official hearings & comment (capitol.texas.gov) →SourceLegiScan (CC BY 4.0)hearing schedule